PDA Series Digial Pressure Transmitter

 FEATURES

  • Ranges 0-30” Hg Vacuum to 0-5800 PSIG
  • Fully Scalable 4-20 mA Output
  • Accuracy ±0.5% of Full Scale
  • Large Easy to Read LED Display
  • Ceramic Pressure Sensing System for High Cycle Life
  • Ranges 0-30” Hg Vacuum to 0-5800 PSIG
  • Fully Scalable 4-20 mA Output
  • Accuracy ±0.5% of Full Scale
  • Large Easy to Read LED Display
  • Ceramic Pressure Sensing System for High Cycle Life

 


GENERAL DESCRIPTION


The PDA series digital pressure transmitter integrates the latest solid state sensing technology into a very versatile, simple to operate package. Programming features include programmable span adjustment, pulsation dampening, zero (tare) adjustment and user settable lockout code. The ceramic sensing system ensures an exceptionally long cycle life with virtually no calibration drift. These features along with the compact, robust stainless steel package make the PDA an ideal choice for OEM applications.

 


SPECIFICATIONS


Measuring Ranges: 0-30” Hg vacuum to 0-5800 PSIG
Display Type: 3 digit LED
Accuracy: ±0.5% of full scale
Sensor Element: Piezoresistive bceramic
Operating Temp. Range
Process & Compensated
Medium: -4 to 176°F
Ambient: -4 to 140°F
Overpressure Ratings:
-30” Hg to 
1450 PSIG: 2x Max. range
>1450 PSIG: 1.5x Max. range
Process Wetted Parts
Sensing Element: Ceramic
Connection: 316L SS
O-Ring: Viton: 
others available on request
Housing Material: 
304 Stainless Steel
Response Time:
 0.5 Sec.
Dampening: Programmable averaging over 1, 2, 4, 8, 16, 32 or 64 samples
Electrical Data
Power Supply: 24 VDC ±20%, 80 mA max.
Output: 0(4)-20 mA 3-wire
Max. Loop Burden: 500 ohms
Electrical
Connection: 4-Pin Micro-DC male (mating connector sold as accessory)
Electrical
Protection: NEMA 4/IP 65

 


ORDERING INFORMATION


PDA Series Digial Pressure Transmitter

 


DIMENSIONS


PDA Series Digial Pressure Transmitter