RCD - Ultra-Rugged Differential Pressure Flowmeter

 FEATURES

  • 0.15-1 to 85-600 GPM Liquids
  • 2.5-25 to 300-1700 SCFM Gases
  • 1/2” to 3” Line Sizes
  • Bronze or 316-Ti Stainless Steel
  • Mechanical Indicator, Digital Indicator, Transmitters and Switches Available
  • Custom Calibrations for Density and Viscosity


GENERAL DESCRIPTION


The RCD series differential pressure flowmeter measures flows of liquids and compressed gases using the orifice principle. The orifice, located in the flow body, generates a differential pressure which varies with flowrate. The differential pressure is applied to a measuring bellows. The measuring bellows is linked either to a mechanical indicator, or to a hall effect sensor, which is input to a compact or full featured electronic display and controller.The unique design features a single measuring bellows making its accuracy unaffected by system pressure fluctuations. The meter movement is a single fulcrum lever design which is simple, yet very reliable, with a minimum of wear parts. The RCD is available with bronze or stainless steel bodies ranging in size from 1/2” NPT to 3” NPT. The various electronic display and control units offer a variety of options such as digital or bargraph displays, adjustable switches and flow transmitters.


SPECIFICATIONS


Flow Ranges
Liquids: 1 to 7 GPM through 100 to 600 GPM
Gases: 2.5-25 SCFM through 300 to 1700 SCFM
Accuracy: ±3% of full scale
Repeatability: ±1% of full scale
Maximum Temperature:
Mechanical Display: 212°F
Electronic Display: 176°F
Maximum Pressure: 580 PSIG
Maximum Pressure Drop: 5 PSI
Indicator Housing: Epoxy coated aluminum, polycarbonate, NEMA 4X
Wetted Materials
Bronze Versions: Bronze, 316-Ti stainless steel, buna-n
SS Versions: 316-Ti stainless
RCD-Z Mechanical Indicator

RCD-Z Mechanical Indicator

  • Flow Units
    • Liquid: GPM
    • Gases: SCFM
  • Optional: LPM, M3/Hr, special scales on request
  • Enclosure: Epoxy coated aluminum & polycarbonate, NEMA 4X
RCD-C Compact Electronics

RCD-C Compact Electronics

  • Input Power: 24 VDC ±20%, 80 mA
  • Display: 3 digit LED
  • Switch: PNP or NPN open collector, 300 mA Max. short circuit protected
  • Flow Transmitter: 4-20 mA 3 wire
  • Housing: 304 SS, NEMA 4X
  • Electrical Connection: Micro-DC male, 5-pin
RCD-K Digital & Bargraph Display/Controller

RCD-K Digital & Bargraph Display/Controller

  • Input Power: 115 VAC, 24 VDC, 24 VAC, 48 VAC or 230 VAC
  • Display: 3-1/2 Digit LED and Bargraph, 270°
  • Relays: 2 SPDT programmable setpoint, 5 amps @ 230 VAC
  • Flow Transmitter: 4-20 mA, 4-wire
  • Enclosure: Epoxy coated aluminum & polycarbonate, NEMA 4X

ORDERING INFORMATION


RCD - Ultra-Rugged Differential Pressure Flowmeter

Ordering Codes For Gas Flowmeters

RCD - Ultra-Rugged Differential Pressure Flowmeter

HOW TO ORDER
To Properly Specify the RCD Series:

  1. Choose the ordering code for the desired range, materials and available fitting size (RCD-1105SN4).
  2. Choose the ordering code for the desired indicator type (e.g. mechanical, compact, etc.)
  3. Choose the codes for the flowmeter installed flow direction (required for mechanical indicator only):
    LT = Flow from left to right
    RT = Flow from right to left
    BL = Vertical up flow, dial on left
    BR = Vertical up flow, dial on right
  4. Specify the process media: 

    Liquids - Specify the type of liquid. If other than water, specify the viscosity and the specific gravity or density. Use option codes C or V as necessary. The RCD will be calibrated for these conditions.

    Gases -specify the type of gas. Specify the normal operating pressure and temperature. The RCD will be calibrated for these conditions.

    NOTE: Calibrations for compressed gases or liquids other than water may change the measuring range from those listed in the part number tables. Contact Flow Network to determine the corrected flow range which will be provided based on operating conditions.

    RCD Installation Piping Requirements In order to guarantee accurate readings, the RCD series must be installed with a minimum of 10 diameters of straight piping at the inlet and 5 diameters of straight piping at the outlet. This straight piping must be the same diameter as the flowmeter fittings and should have no bends, elbows, tees, valves or other plumbing appurtenances.

 

 


DIMENSIONS


RCD-Z Mechanical Indicator
RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD-C Compact Electronics

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD-K

 

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter