General Description
The EDM turbine flowmeter measures the flow of water and low viscosity
liquids ranging from 0.3 GPM to 300 GPM. Its replaceable lithium
battery powers an onboard rate meter/totalizer allowing installation
in virtually any location, regardless of power availability. Results
are displayed on a highly visible LCD readout. Except for units
with a flow rate transmission feature, the EDM is also FM approved
for operation in Class I, II, and III Division 1 hazardous areas.
Versatile and easy to use, the EDM’s modular design allows
us to offer a variety of electronic modules which further enhance
its versatility. Available are options for a remote display, a frequency
output, and a 4-20 mA analog transmitting output. Nylon, aluminum,
PVC, PVDF or stainless steel body construction make the EDM compatible
with a wide variety of process media.
Improved Computer Electronics
The upgraded computer electronics features 1 rate and 2 totalizing
displays. Standard measuring units are field switchable GPM or LPM.
The ability to store two field calibrations allows the user to freely
switch 3 different liquid viscosities with the same flowmeter.
Specifications
 |
Accuracy
(% of Reading)
See ordering information
Fittings
Standard: NPT
Optional: ISO, flanges Tri-clamp®
Maximum Pressure
Stainless Steel
- Threaded: 1500 PSIG
- Flanged: 285 PSIG
- Tri-clamp: 450 PSIG
Nylon: 150 PSIG
Aluminum: 300 PSIG
PVDF/PVC: 150 PSIG
Temperature Range (Operating)
Onboard Display: +14 to +140°F
Remote Display
- SS/Aluminum: -40 to +250°F
- Nylon/PVDF: -20 to 180°F
- PVC: +32 to 140°F
Display + Output: +14 to +140°F |
Wetted Materials
SS Body: 316 SS, Ceramic, Tungsten Carbide,
PVDF
Nylon Body: Nylon, Ceramic, Tungsten Carbide,
Manganese/zinc, 316 SS
Aluminum Body: Aluminum, 316 SS, Tungsten
Carbide, Ceramic, Manganeze/zinc
PVDF Body: PVDF, ceramic, viton
PVC Body: PVC, PVDF, ceramic, viton
Electrical Ratings
Onboard Display/Computers
Input Power: Two 3 VDC lithium batteries
Battery
Life: 9000 hours
Protection: NEMA 4
Intrinsic Safety: FM Approved Class I, II,
III Div. 1, Group A-G
Option -RD: Remote Display Kit
Input Power: Self-powered magnetic pickup
Cable Length: 10 ft supplied, 100 ft maximum
Protection: NEMA 4 |
 |
Ordering Information

Electrical Characteristics of Standard Pulse and Analog
Outputs
Option -WM:
4-20 mA Transmitter
Input Power: 7-30 VDC loop powered
Output: 2-wire, 4-20 mA DC
Cable Length: 10 feet provided
Protection: NEMA 4
Intrinsic Safety: None |
Option -PM:
Pulse Transmitter with Display
Input Power: 0-60 VDC
Output: NPN open collector transistor
Sink Current: 100 mA maximum
Cable Length: 10 feet provided
Protection: NEMA 4
Intrinsic Safety: None |
Option -SC:
Pulse Transmitter, no Display
Input Power: 9-35 VDC
Output: NPN open collector transistor
Sink Current: 4 mA maximum
Cable Length: 10 feet provided
Protection: NEMA 4
Intrinsic Safety: None |
Electrical Characteristics of Intrinsically Safe Options
Intrinsically Safe Pulse Transmitter
Power Supply: 7.5-30 VDC Max. Allowable
Output: NPN open collector Cable Length: 100 Ft.
Protection: NEMA 4 Required Cable: Belden #9501
to maintain I.S. approval
Intrinsic Safety: FM approved, Class I, Div. Div.
I, Gr. A,B,C,D,E,F,G
Mating Connector sold separately
Part#: EDM-ACC1135240
|
Intrinsically Safe Remote Kit
Max. Allowable
Cable Length: 100 Ft.
Required Cable: Belden #9501 to maintain I.S. approval
Protection: NEMA 4
Intrinsic Safety: FM approved Class I, II, III
Div. 1, Gr. A,B,C,D,E,F,G
|
Dimensions
EDM Electronic Water Meter

|
- Economical PVC Construction
- Flowrate Indication with Resettable and Non-Resettable
Totalizers
- Flow Ranges 1-10 GPM through 20-200 GPM Water
- Lithium Battery Powered Indicator Requires no Local Supply
Power
- Excellent Replacement for Mechanical Totalizers
|
The EDM series water flowmeter is excellent for accurately
totalizing water and other low viscosity liquids. It features
an economical PVC body and lithium battery powered LCD display.
The display has a resettable batch totalizer and a nonresettable
grand totalizer, as well as rate indication. These displays
are accessed by a toggle pushbutton on the face. The EDM is
factory calibrated for water flow. This calibration is valid
for low viscosity liquids up to 10 centistokes viscosity.
For higher viscosity liquids, a field calibration mode exists
allowing the user to dispense a known volume of liquid in
order to calibrate the EDM’s computer for the higher
viscosity liquid.
The EDM electronic water meter is available
in line sizes from 1/2 to 2 inches. Fittings available are
PVC socket or NPT threads. The EDM series combines economy
with a full featured electronics making it an excellent and
economical replacement for metal body mechanical water totalizers.
Onboard Display Features
Flowrate indication, one user resettable
batch totalizer, one non-resettable grand totalizer, field
calibration routine for higher viscosity liquids (100 cPs
Max.). |
 |
Specifications
Available Flow Ranges: 1-10 GPM through
20-200 GPM water
Allowable Liquids: Clean non-coating liquids
compatible the with wetted parts
Accuracy: ±3% of reading
Repeatability: ±0.1% of reading
Max. Pressure: 150 PSIG @70°F
Oper. Temp. Range: 32 to 140°F
Straight Piping Rqmt: 10 x D upstream, 5
x D downstream
Wetted Parts
Body: PVC
Rotor: PVDF (Kynar®)
Bearings: Ceramic
Axle: Tungsten carbide
Retaining Ring: 316 SS
|
Display Power Source: 2 x 1.5V lithium batteries
Battery Life: 9000 hours of continuous use
Power Saver Feature: Display blanks when
flow ceases for longer than one minute.
Filtration Required
1/2” and 3/4”: 55 mesh
1”, 1-1/2” & 2”: 28
mesh |
Ordering Information
|